The indoor environment in any building is a result of interaction between the
site, climate, building system, construction techniques, contaminant sources and
building occupants. Each of these components is directly affected by the other
and when one adversely affects the other, the indoor air quality could be
altered negatively.
Nova Environmental, Inc. has personnel specially trained to investigate
potential indoor air quality problems. Our indoor air quality team uses a
systematic problem-solving approach employing state-of-the-art equipment to
locate and assess potential sources of indoor air quality problems and/or
complaints.

Nova Environmental, Inc. specialists will study each of four factors (HVAC
system, potential sources, pathways and occupants) affecting indoor air quality.
Occupant activity, temperature and relative humidity are sampled/analyzed while
specific contaminant sampling may also need to be conducted (i.e. insecticides,
volatile organic compounds or bioaerosols). Finally, Nova Environmental, Inc.
Indoor Air Quality Specialists will provide a thorough report identifying all
sampling and analytical results, including a determination of probable air
quality problems and remediation recommendations. Therefore, it is Nova
Environmental, Inc.'s goal to determine and identify potential indoor air
problems, advise resolutions and provide preventive measures to alleviate future
concerns.

Nova Environmental, Inc.'s Indoor Air Quality Staff received specialized
training through a course sponsored by the National Institute for Occupational
Safety and Health (NIOSH). Nova Environmental, Inc. follows "Building Air
Quality" guidelines as provided by the Environmental Protection Agency (EPA) and
NIOSH.
Nova Environmental Inc. utilizes the following systematic procedures during
mold investigations.
- Visual inspections for obvious moisture damage of building materials or
fungal contamination.
- Bulk sampling of obvious fungal contamination for fungal species
identification.
- Air sampling for both viable and non-viable airborne concentrations in areas
of concerns as well as in indoor and outdoor locations necessary for comparative
analysis.
- Recommendations for cleaning and/or mold remediation based upon above
procedures.

In addition to providing consultation services on potential IAQ problems,
Nova Environmental Inc. can provide standard operating procedures and policies
for identifying, responding and resolution techniques to facilities. This IAQ
Management Plan incorporates the site specific adaptation for the best
allocation of resources for an individual entity. This versatility allows for
the generation of a program that will best suit the client.

|